FUJITSU

PRODUCT | VRF SYSTEM |CONTROL SYSTEM & CONTROLLER SERIES

Airstage™ (VRF Systems)

Control System & Controller

Control System

Control System.Every user's needs are supported by offering a variety of controls, such as individual control, central control and building management control options.

Comparison table of Controllers

Item
Wired Remote Controller (Touch panel)

Wired Remote Controller

Simple Remote Controller

Simple Remote Controlle*1

Wireless Remote Controller
Model name UTY-RNRY UTY-RNKY UTY-RSKY UTY-RHKY UTY-LNHY
Max. controllable remote controller groups 1 1 1 1 1
Max. controllable indoor units 16 16 16 16 16
Max. controllable groups - - - - -
Air conditioning control function On / Off UTY-RNRY is Supported UTY-RNKY is Supported UTY-RSKY is Supported UTY-RHKY is Supported UTY-LNHY is Supported
Operation mode setting UTY-RNRY is Supported UTY-RNKY is Supported UTY-RSKY is Supported - UTY-LNHY is Supported
Fan speed setting UTY-RNRY is Supported UTY-RNKY is Supported UTY-RSKY is Supported UTY-RHKY is Supported UTY-LNHY is Supported
Room temp. setting UTY-RNRY is Supported UTY-RNKY is Supported UTY-RSKY is Supported UTY-RHKY is Supported UTY-LNHY is Supported
Room temp. set point limitation UTY-RNRY is Supported - - - -
Test operation UTY-RNRY is Supported UTY-RNKY is Supported UTY-RSKY is Supported - UTY-LNHY is Supported
Up/down air direction flap setting UTY-RNRY is Supported UTY-RNKY is Supported - - UTY-LNHY is Supported
Right/left air direction flap setting UTY-RNRY is Supported UTY-RNKY is Supported - - UTY-LNHY is Supported
Group setting - - - - -
RC prohibition - - - - -
Anti freeze setting UTY-RNRY is Supported - - - -
Economy mode setting UTY-RNRY is Supported UTY-RNKY is Supported - - UTY-LNHY is Supported
Display Failure UTY-RNRY is Supported UTY-RNKY is Supported UTY-RSKY is Supported UTY-RHKY is Supported -
Defrosting UTY-RNRY is Supported UTY-RNKY is Supported UTY-RSKY is Supported UTY-RHKY is Supported -
Current time UTY-RNRY is Supported UTY-RNKY is Supported - - UTY-LNHY is Supported
Day of week UTY-RNRY is Supported UTY-RNKY is Supported - - -
R.C. prohibition UTY-RNRY is Supported UTY-RNKY is Supported UTY-RSKY is Supported UTY-RHKY is Supported -
Cooling/heating priority UTY-RNRY is Supported UTY-RNKY is Supported UTY-RSKY is Supported UTY-RHKY is Supported -
Address display UTY-RNRY is Supported UTY-RNKY is Supported UTY-RSKY is Supported UTY-RHKY is Supported -
Room temp UTY-RNRY is Supported - - - -
Multi language UTY-RNRY is Supported - - - -
Summer time UTY-RNRY is Supported - - - -
Name registration UTY-RNRY is Supported - - - -
Backlight UTY-RNRY is Supported - UTY-RSKY is Supported UTY-RHKY is Supported -
2 Dfloor layout / 3D building display - - - - -
Timer Schedule timer Period Week Week - - -
On/Off,Temp,mode,times per day 8 4 - - -
On/off timer UTY-RNRY is Supported UTY-RNKY is Supported - - UTY-LNHY is Supported
Sleep timer - - - - UTY-LNHY is Supported
Program timer - - - - UTY-LNHY is Supported
Auto off timer UTY-RNRY is Supported - - - -
Day off UTY-RNRY is Supported UTY-RNKY is Supported - - -
Min. unit of timer setting (Minutes) 10 • 30 30 - - 5
Control Status monitoring system - - - - -
Electricity charge apportionment - - - - -
Error history UTY-RNRY is Supported UTY-RNKY is Supported UTY-RSKY is Supported UTY-RHKY is Supported -
Emergency stop - - - - -
Remote management - - - - -
Energy saving management - - - - -
E-mail notification for malfunction - - - - -
Key lock UTY-RNRY is Supported
Child lock
- - - -
Item
Group Remote Controller

Central Remote Controller

Touch Panel Controller

System Controller Lite (Software)

System Controller (Software)
Model name UTY-CGGY UTY-DCGY UTY-DTGY UTY-ALGX UTY-APGX
Max. controllable remote controller groups 8 100 400 400 1600
Max. controllable indoor units 128 100 400 400 1600
Max. controllable groups - 16 400 400 1600
Air conditioning control function On / Off UTY-CGGY is Supported UTY-DCGY is Supported UTY-DTGY is Supported UTY-ALGX is Supported UTY-APGX is Supported
Operation mode setting UTY-CGGY is Supported UTY-DCGY is Supported UTY-DTGY is Supported UTY-ALGX is Supported UTY-APGX is Supported
Fan speed setting UTY-CGGY is Supported UTY-DCGY is Supported UTY-DTGY is Supported UTY-ALGX is Supported UTY-APGX is Supported
Room temp. setting UTY-CGGY is Supported UTY-DCGY is Supported UTY-DTGY is Supported UTY-ALGX is Supported UTY-APGX is Supported
Room temp. set point limitation - UTY-DCGY is Supported UTY-DTGY is Supported UTY-ALGX is Supported UTY-APGX is Supported
Test operation - UTY-DCGY is Supported UTY-DTGY is Supported - -
Up/down air direction flap setting - UTY-DCGY is Supported UTY-DTGY is Supported UTY-ALGX is Supported UTY-APGX is Supported
Right/left air direction flap setting - UTY-DCGY is Supported UTY-DTGY is Supported UTY-ALGX is Supported UTY-APGX is Supported
Group setting - UTY-DCGY is Supported UTY-DTGY is Supported UTY-ALGX is Supported UTY-APGX is Supported
RC prohibition - UTY-DCGY is Supported UTY-DTGY is Supported UTY-ALGX is Supported UTY-APGX is Supported
Anti freeze setting - UTY-DCGY is Supported UTY-DTGY is Supported UTY-ALGX is Supported UTY-APGX is Supported
Economy mode setting - UTY-DCGY is Supported UTY-DTGY is Supported UTY-ALGX is Supported UTY-APGX is Supported
Display Failure UTY-CGGY is Supported UTY-DCGY is Supported UTY-DTGY is Supported UTY-ALGX is Supported UTY-APGX is Supported
Defrosting - UTY-DCGY is Supported UTY-DTGY is Supported UTY-ALGX is Supported UTY-APGX is Supported
Current time UTY-CGGY is Supported UTY-DCGY is Supported UTY-DTGY is Supported UTY-ALGX is Supported UTY-APGX is Supported
Day of week UTY-CGGY is Supported - UTY-DTGY is Supported UTY-ALGX is Supported UTY-APGX is Supported
R.C. prohibition UTY-CGGY is Supported UTY-DCGY is Supported UTY-DTGY is Supported UTY-ALGX is Supported UTY-APGX is Supported
Cooling/heating priority UTY-CGGY is Supported UTY-DCGY is Supported UTY-DTGY is Supported UTY-ALGX is Supported UTY-APGX is Supported
Address display UTY-CGGY is Supported UTY-DCGY is Supported UTY-DTGY is Supported UTY-ALGX is Supported UTY-APGX is Supported
Room temp - - - - -
Multi language - UTY-DCGY is Supported UTY-DTGY is Supported UTY-ALGX is Supported UTY-APGX is Supported
Summer time - UTY-DCGY is Supported UTY-DTGY is Supported UTY-ALGX is Supported UTY-APGX is Supported
Name registration - UTY-DCGY is Supported UTY-DTGY is Supported UTY-ALGX is Supported UTY-APGX is Supported
Backlight - UTY-DCGY is Supported UTY-DTGY is Supported - -
2 Dfloor layout / 3D building display - - - - UTY-APGX is Supported
Timer Schedule timer Period Week Week Year Year Year
On/Off,Temp,mode,times per day 4 20 20 144 144
On/off timer - - - - -
Sleep timer - - - - -
Program timer - - - - -
Auto off timer - - - - -
Day off - UTY-DCGY is Supported UTY-DTGY is Supported UTY-ALGX is Supported UTY-APGX is Supported
Min. unit of timer setting (Minutes) 10 10 10 10 10
Control Status monitoring system - UTY-DCGY is Supported UTY-DTGY is Supported UTY-ALGX is Supported UTY-APGX is Supported
Electricity charge apportionment - - - UTY-ALGX is Optional function UTY-APGX is Supported
Error history UTY-CGGY is Supported UTY-DCGY is Supported UTY-DTGY is Supported UTY-ALGX is Supported UTY-APGX is Supported
Emergency stop - UTY-DCGY is Supported*2 UTY-DTGY is Supported*2 - -
Remote management - - - UTY-ALGX is Optional function UTY-APGX is Supported
Energy saving management - - - UTY-ALGX is Optional function UTY-APGX is Optional function
E-mail notification for malfunction - - - UTY-ALGX is Supported UTY-APGX is Supported
Key lock UTY-CGGY is Supported
Child lock
UTY-DCGY is Supported
Password setting
UTY-DTGY is Supported
Password setting
UTY-ALGX is Supported
Password setting
UTY-APGX is Supported
Password setting

: Supported   : Optional function

*1 :
"Operation mode" setting is not available for this model.
*2 :
This function is available only through external input. control.

 

Top of Page


ribbon