FUJITSU

PRODUCT | VRF SYSTEM | V-II TROPICAL SERIES

AIRSTAGE™ V-II Tropical Series

Heat Pump

Fujitsu General tropical VRF is designed for tropical weather. High performance is achieved even at high outdoor temperatures by using of high outdoor temperature compatible electronic parts, large heat exchanger, high performance rotary compressor, and high performance inverter control. (For more information, please refer to download the catalog.)

Photo of model name AJY072LNLAH
22.4kW (8HP)
AJY072LNLAH

Photo of model name AJY072LNLAH
28.0kW (10HP)
AJY090LNLAH

Photo of model name AJY126LNLAH
40.0kW (14HP)
AJY126LNLAH


Features

High ambient operation design

  • Possible to operate cooling up to 52ÂșC outdoor temperature.

Image of High ambient operation design

Powerful cooling capacity design

  • Keeping high cooling power at even high ambient temperature.

Image of Powerful cooling capacity design

Anti-corrosion treatment design

  • All metalic and PCB components are protected against corrosion.

Image of Anti-corrosion treatment design

Outdoor units lineup

  Space saving combination Energy efficiency combination
8HP AJY072LNLAH
10HP AJY090LNLAH  
14HP AJY126LNLAH  
16HP AJY144LNLAH  
18HP AJY162LNLAH  
20HP AJY180LNLAH  
22HP AJY198LNLAH  
24HP AJY216LNLAH AJY216LNLAH(Energy Effieciency)
26HP   AJY234LNLAH(Energy Effieciency)
28HP AJY252LNLAH AJY252LNLAH(Energy Effieciency)
30HP AJY270LNLAH  
32HP AJY288LNLAH  
34HP AJY306LNLAH  
36HP AJY324LNLAH  
38HP AJY342LNLAH  
42HP AJY378LNLAH  

 

Features

Efficiency in actual operation

Top class high COP is realized for all combinations by our unique heat exchanger structure, high efficient DC twin compressor, and other our own technologies.

Space saving combination

COP value 8HP-4.37,10HP-4.02.12HP-4.04,14HP-3.93,16HP-3.97,18HP-4.17,20HP-4.17,22HP-4.03,24HP-4.04,26HP-3.98,28HP-4.00,30HP-3.95,32HP-3.97,34HP-4.04,36HP-4.04,38HP-4.00,40HP-4.01,42HP-3.98,44HP-3.99,46HP-3.96,48HP-3.97.

Energy efficiency combination

COP value 16HP-4.37,22HP-4.08,24HP-4.37,26HP-4.23,28HP-4.22,30HP-4.15,32HP-4.12,34HP-4.06,36HP-4.02,40HP-3.96,42HP-3.93,44HP-3.94.

Energy efficiency is 12% up COP value than Space saving.(For 24 HP Combination)


Energy saving technology that boosted operation efficiency

Powerful large propeller fan

By using CFD*1 technology, A newly designed fan achieves high performance and low noise operation.

*1. CFD = Computational Fluid Dynamics


DC fan motor

Power consumption has been reduced by 25% compared to previous models by using a compact and high performance DC fan motor.


Subcool heat exchanger

High Heat Exchange efficiency is achieved by using an internal projection shape double pipe construction.


Sine-wave DC inverter control

High efficiency operation is realized by using a sine wave DC inverter control.


DC twin rotary compressor

Significantly greater efficiency is realized by use of a large capacity DC twin rotary compressor with substantially increased refrigerant intake and compression efficiency.


Outdoor unit illustration


4-face heat exchanger

Heat exchange efficiency is significantly improved by the introduction of a new 4-face heat exchanger that increases effective surface area.


Front intake port(corner cut air inhaling structure)

In multiple outdoor unit installations, the unique front intake design improves airflow into the Heat Exchanger.


 

Top of Page